{"product_id":"maxiflame-hb-solar-xl-solar-group-double-pipe-for-high-flow-systems","title":"Maxiflame HB SOLAR XL solar group – double pipe for high flow systems","description":"\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e\u003cstrong\u003eMaxiflame HB SOLAR XL solar group – double pipe for high flow systems\u003c\/strong\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The \u003cstrong\u003eMaxiflame HB SOLAR XL\u003c\/strong\u003e is a \u003cstrong\u003ecomplete solar station\u003c\/strong\u003e designed for the control, circulation and management of the heat transfer fluid in solar thermal systems.\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e In practice, it is the \u003cstrong\u003eoperational heart of the solar system\u003c\/strong\u003e : the component that allows the heat to be transferred from the solar panels to the storage tank (boiler or buffer tank), ensuring efficiency, safety and consistent performance over time.\u003c\/p\u003e\u003ch2 style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e What it is and what it is used for\u003c\/h2\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e HB SOLAR XL is a \u003cstrong\u003ehigh flow double tube solar group\u003c\/strong\u003e , designed for:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e manage the heat produced by solar collectors\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e transfer it to the ACS boiler or inertial storage tank\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e check the flow and pressure of the circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e In a solar thermal system, without this group:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e heat is not distributed properly\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e the system loses efficiency\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e the risk of malfunctions increases\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e Where to use it\u003c\/h2\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e It is designed for:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e advanced domestic solar thermal systems\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e systems with \u003cstrong\u003emultiple solar collectors\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e systems for the production \u003cstrong\u003eof domestic hot water (DHW)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e systems with storage (puffer or boiler)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e It is particularly suitable for:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e large houses\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e accommodation facilities\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e centralized systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e In fact, it is designed for \u003cstrong\u003ehigh flow and higher power systems\u003c\/strong\u003e\u003c\/p\u003e\u003ch2 style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e How it works\u003c\/h2\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The operation is simple but fundamental:\u003c\/p\u003e\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e Solar panels heat the heat transfer fluid\u003c\/li\u003e\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The HB SOLAR XL group activates the \u003cstrong\u003ecirculation pump\u003c\/strong\u003e\n\u003c\/li\u003e\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The hot fluid is transferred to the storage tank\u003c\/li\u003e\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The system regulates:\u003cul\u003e\n\u003cli\u003e flow rate (flowmeter)\u003c\/li\u003e\n\u003cli\u003e pressure\u003c\/li\u003e\n\u003cli\u003e safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e Everything happens in a controlled and continuous manner.\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The installation data sheet (attached) clearly shows the central role of the group between collectors and boiler.\u003c\/p\u003e\u003ch2 style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e Why it is advantageous\u003c\/h2\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e This module integrates into a single system:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e circulation pump\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e flowmeter for flow control\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e safety valve and pressure gauge\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e venting systems and gravity brakes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e In this way:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e optimizes heat transfer\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e improves system efficiency\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e reduces consumption and waste\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e increases safety and durability over time\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e It is particularly advantageous in systems with multiple collectors or high flow rates, where precise and stable control is required.\u003c\/p\u003e\u003ch2 style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e Installation\u003c\/h2\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The HB SOLAR XL group is installed between the \u003cstrong\u003esolar collectors and the storage tank\u003c\/strong\u003e , becoming the central point of the solar circuit.\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e It mounts to the wall in a vertical position and connects:\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e to the panel circuit (solar flow and return)\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e to the accumulation (boiler or buffer)\u003c\/li\u003e\n\u003cli style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e to the regulation system (control unit, optional)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e Installation must be performed by qualified personnel to ensure safety and correct operation.\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e \u003cstrong\u003eTECHNICAL CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e Connections: \u003cstrong\u003e1”\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Flowmeter range: \u003cstrong\u003e5–35 l\/min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e System power: up to \u003cstrong\u003e35 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Collector surface area: up to \u003cstrong\u003e70 m² (high flow)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Pump: \u003cstrong\u003eWilo Para 15\/8 STG\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Max pressure: \u003cstrong\u003e6–10 bar\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Max temperature:\u003cul\u003e\n\u003cli\u003e flow rate: \u003cstrong\u003e140°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e return: \u003cstrong\u003e120°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e Power supply: \u003cstrong\u003e230V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Dimensions: \u003cstrong\u003e377 x 440 x 220 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e \u003cstrong\u003eNB: FOR FURTHER DETAILS WE RECOMMEND VIEWING THE TECHNICAL DATA SHEET ATTACHED.\u003c\/strong\u003e \u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e \u003cstrong\u003eWARRANTY\u003c\/strong\u003e\u003c\/p\u003e\u003cp style=\"\u0026amp;nbsptext-align:justify\u0026amp;nbsp\"\u003e The warranty is the official \u003cstrong\u003eMaxiflame Italia one\u003c\/strong\u003e and lasts \u003cstrong\u003e2 years.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Maxiflame","offers":[{"title":"Default Title","offer_id":53321297363282,"sku":"700905","price":835.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0535\/5110\/4164\/files\/d600d604cfa4f5a5fe5c1226ef762ae7.jpg?v=1777568458","url":"https:\/\/climamarket.com\/en-de\/products\/maxiflame-hb-solar-xl-solar-group-double-pipe-for-high-flow-systems","provider":"ClimaMarket Europe SLU","version":"1.0","type":"link"}