{"product_id":"maxiflame-mx135-2-boiler-thermoproduct-interface-module-with-dhw-production","title":"Maxiflame MX135\/2 Boiler\/Thermoproduct Interface Module with DHW Production","description":"\u003cp\u003e\u003cstrong\u003eMaxiflame MX135\/2 Boiler\/Thermoproduct Interface Module with Instantaneous DHW Production\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eMaxiflame MX135\/2\u003c\/strong\u003e is an interface module designed to integrate a \u003cstrong\u003egas boiler and a biomass thermoproduct\u003c\/strong\u003e , ensuring hydraulic separation of the circuits and compliance with INAIL regulations.\u003c\/p\u003e\n\n\u003cp\u003eUnlike standard models, it integrates a \u003cstrong\u003ethree-circuit plate exchanger\u003c\/strong\u003e that allows the \u003cstrong\u003einstantaneous production of domestic hot water (DHW)\u003c\/strong\u003e , in addition to heating management.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is it for?\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eseparate the circuits between the boiler and the thermoproduct\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eautomatically manage heating\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eproduce instantaneous ACS directly from the module\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eA single solution for a complete system.\u003c\/p\u003e\n\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003ethe boiler works as an initial support\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003ethe thermoproduct takes over when it is at temperature\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003ethe module produces DHW via a dedicated exchanger with \u003cstrong\u003eflow switch and DHW priority\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications: it is designed for systems with TWO generators\u003c\/h3\u003e\n\n\u003cp\u003eThe MX135\/2 is useful when you have:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003ethermoproduct (hydro stove\/thermo fireplace)\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003egas backup boiler\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eand you want:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eseparate circuits (regulatory requirement)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eautomatically manage who works\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eproduce instantaneous DHW without a boiler\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003ePower: \u003cstrong\u003eup to 35-40 kW\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eDHW production: \u003cstrong\u003eup to 12 l\/min\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eSanitary exchanger: \u003cstrong\u003e16\/20 AISI 316 L stainless steel plates\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eCirculator: \u003cstrong\u003eWilo PARA 15\/6 SC\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDifferences from other MX135s\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e✔ \u003cstrong\u003eMX135\/1 → heating only\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e✔ \u003cstrong\u003eMX135\/1V → ACS management (does not produce it)\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e✔ \u003cstrong\u003eMX135\/2 → produces ACS directly\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIt is the most complete module in the range.\u003c\/p\u003e\n\n\u003ch3\u003eWhen to choose it\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eDo you want to eliminate boilers or accumulators?\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eDo you want immediate ACS from the thermoproduct?\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003eyou want a compact and fully integrated system\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNB: FOR FURTHER TECHNICAL SPECIFICATIONS WE RECOMMEND VIEWING THE ATTACHED TECHNICAL DATA SHEET.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePlease note that the technical data sheet does not explicitly report the code 135203. For consultation purposes, it is possible to refer to the code 135201, with which it shares the same technical characteristics, differing only in internal sizing (more powerful and stable exchanger) and power (35-40 kW).\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWARRANTY\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe warranty is the official \u003cstrong\u003eMaxiflame one\u003c\/strong\u003e and lasts \u003cstrong\u003e2 years.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Maxiflame","offers":[{"title":"Default Title","offer_id":53011547717970,"sku":"135203","price":1105.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0535\/5110\/4164\/files\/912ae1b15c7801f837e38d17c670f54b_f58d440d-1590-42c6-8e73-5b5da079dbc5.jpg?v=1776157590","url":"https:\/\/climamarket.com\/products\/maxiflame-mx135-2-boiler-thermoproduct-interface-module-with-dhw-production","provider":"ClimaMarket Europe SLU","version":"1.0","type":"link"}